Electrocatalytic sensor devices: (I) cyclopentadienylnickel(II) thiolato Schiff base monolayer self-assembled on gold

Morrin, Aoife orcid logoORCID: 0000-0002-3031-4794, Moutloali, Richard M., Killard, Anthony J. orcid logoORCID: 0000-0001-6953-3655, Smyth, Malcolm R., Darkwa, James and Iwuoha, Emmanuel I. (2004) Electrocatalytic sensor devices: (I) cyclopentadienylnickel(II) thiolato Schiff base monolayer self-assembled on gold. Talanta, 64 (1). pp. 30-38. ISSN 0039-9140

Abstract
The fabrication of a self-assembled monolayer (SAM) of a cyclopentadienylnickel(II) thiolato Schiff base compound, [Ni(SC6H4NC(H)C6H4OCH2CH2SMe)(η5-C5H5)]2 on a gold electrode is described. Effective electronic communication between the Ni(II) centres and the gold surface was established by electrochemically cycling the Schiff base-doped Au electrode in 0.1 M NaOH from −200 mV to +600 mV. The SAM-modified electrode exhibited quasi-reversible electrochemistry. The integrity of this electrocatalytic SAM, with respect to its ability to block and electro-catalyse certain Faradaic processes, was interrogated using cyclic voltammetric experiments. The formal potential, E°′, varied with pH to give a slope of about −30 mV pH−1. The surface concentration, G, of the nickel redox centres was found to be 1.548×10−11 mol cm−2. By electrostatically doping the SAM using an applied potential of +700 mV versus Ag/AgCl, in the presence of horseradish peroxidase (HRP), it was fine-tuned for amperometric determination of H2O2. The electrocatalytic-type biosensor displayed typical Michaelis–Menten kinetics and the limit of detection was found to be 6.25 mM.
Metadata
Item Type:Article (Published)
Refereed:Yes
Uncontrolled Keywords:self-assembled monolayer; cyclopentadienylnickel(II) thiolato schiff base; biosensor; electrostatic doping; horseradish peroxidase;
Subjects:Physical Sciences > Electrochemistry
Physical Sciences > Chemistry
Biological Sciences > Biosensors
DCU Faculties and Centres:DCU Faculties and Schools > Faculty of Science and Health > School of Chemical Sciences
Research Initiatives and Centres > National Centre for Sensor Research (NCSR)
Publisher:Elsevier
Official URL:http://dx.doi.org/10.1016/j.talanta.2003.11.046
ID Code:56
Deposited On:08 Nov 2006 by DORAS Administrator . Last Modified 27 Sep 2019 11:19
Documents

Full text available as:

[thumbnail of electocatalytic_sensor_devices.pdf]
Preview
PDF - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
1MB
Downloads

Downloads

Downloads per month over past year

Archive Staff Only: edit this record