Rafferty, Aran ORCID: 0000-0001-6388-7735, Bakir, S., Brabazon, Dermot ORCID: 0000-0003-3214-6381 and Prescott, Tim (2009) Calibration and characterisation with a new laser-based magnetostriction measurement system. Materials & Design, 30 (5). pp. 1680-1684. ISSN 0261-3069
Abstract
A laser-based magnet measurement system has been developed to measure the magnetostrictive strain of large cylindrical samples. The measurement system incorporates a solenoid capable of generating a maximum magnetic field intensity of 3000 Oe and a laser displacement sensor. For calibration and evaluation purposes, the positive magnetostrictions of two different types of giant magnetostrictive Tb–Dy–Fe-based materials were accessed with this system. A magnetostrictive strain of 622 ppm was obtained at 3000 Oe for TbxDy1-xFe2-y, compared with 725 ppm for Tb0.27Dy0.73Fe2. A rod of sintered cobalt ferrite was also measured. This exhibited negative magnetostriction, with a maximum contraction of 260 ppm at 3000 Oe.
Metadata
Item Type: | Article (Published) |
---|---|
Refereed: | Yes |
Uncontrolled Keywords: | Magnetostriction; Magnetic field strength; Terfenol-D; Cobalt ferrite |
Subjects: | Engineering > Materials Engineering > Mechanical engineering |
DCU Faculties and Centres: | DCU Faculties and Schools > Faculty of Engineering and Computing > School of Mechanical and Manufacturing Engineering |
Publisher: | Elsevier |
Official URL: | http://dx.doi.org/10.1016/j.matdes.2008.07.026 |
Copyright Information: | © 2009 Elsevier |
Use License: | This item is licensed under a Creative Commons Attribution-NonCommercial-Share Alike 3.0 License. View License |
ID Code: | 20354 |
Deposited On: | 19 Dec 2014 14:38 by Fran Callaghan . Last Modified 20 Sep 2018 10:38 |
Documents
Full text available as:
Preview |
PDF
- Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
636kB |
Downloads
Downloads
Downloads per month over past year
Archive Staff Only: edit this record