Login (DCU Staff Only)
Login (DCU Staff Only)

DORAS | DCU Research Repository

Explore open access research and scholarly works from DCU

Advanced Search

Investigation of plasma processes in surface Modification with biodiagnostic applications

Coyle, Conor (2012) Investigation of plasma processes in surface Modification with biodiagnostic applications. PhD thesis, Dublin City University.

Abstract
Plasma enhanced chemical vapour deposition was investigated for the deposition of bioactive surfaces which can be categorised into two functions. The first is in biosensor applications, immunoassay biodevices have been researched considerably but significant problems remain in particular non-specific adsorption. This work demonstrates a new method of reducing the non specific adsorption on the surface of cyclo olefin polymers for use as immunoassay biodevices. PECVD deposition of a silicon oxide bonding layer followed by an acrylic acid functional layer which contains carboxylic acid functional groups on cylic olefin polymers is achieved. The deposited film exhibits low non-specific adsorption of non target analytes and increased covalent attachment of target analytes. A comprehensive characterisation of the deposition is carried out and conclusions of the mechanisms involved in creating the surface are elucidated; surfaces are analysed using a combination of quantitative and qualitative approaches. The mechanisms behind the plasma deposition of acrylic acid are investigated and methods to increase carboxylic retention on the surface are considered, in particular the influence of background gas is investigated. The function of the second surface is in anti-fouling devices. The production of antifouling films is a key element for the development of biomedical materials such as medical devices and implants. Anti-fouling coatings favour the biological integration by limiting the interactions between the implants and physiological fluids. Proteins present in the blood will be the first components to become adsorbed on the surface of the biomaterial. Fibrinogen present in the blood is the major initiator of inflammatory reactions and is involved in blood clotting. By minimising fibrinogen adsorption it is possible to reduce the contribution of the biomaterial surface characteristics to thrombosis and inflammatory reactions. Here in, a method to reduce fibrinogen adsorption is discussed and a characterisation of the plasma phase used to deposit the antifouling coating is investigated and a study on the properties of the surface for antifouling is examined. Using HMDSO and oxygen ‘polymer-like’ and ‘silica-like’ surfaces can be deposited, silica-like depositions when compared to the polymer-like depositions displayed lower fibrinogen adsorption, 42% compared to 23%.
Metadata
Item Type:Thesis (PhD)
Date of Award:November 2012
Refereed:No
Supervisor(s):Swift, Paul and Daniels, Stephen
Uncontrolled Keywords:Bioactive Surfaces; Immunoassays; Non-Specific Adsorption
Subjects:Physical Sciences > Plasma processing
Biological Sciences > Biosensors
DCU Faculties and Centres:DCU Faculties and Schools > Faculty of Science and Health > School of Physical Sciences
Use License:This item is licensed under a Creative Commons Attribution-NonCommercial-No Derivative Works 3.0 License. View License
ID Code:17475
Deposited On:03 Dec 2012 14:38 by Paul Swift . Last Modified 19 Jul 2018 14:57
Documents

Full text available as:

[thumbnail of PhD_Thesis_Conor_Coyle_2012_final.pdf]
Preview
PDF - Requires a PDF viewer such as GSview, Xpdf or Adobe Acrobat Reader
55MB
Downloads

Downloads

Downloads per month over past year

Archive Staff Only: edit this record